Stratophase

Key Benefits

  • Immunoassay compatible
  • Tag free detection
  • Greater specificity
  • High Speed
  • Robust solid state optical

Sensing Applications

SpectroSens detection system

Stratophase produce two ranges of products applicable to sensing. Firstly the SpectroSens biochemical sensors provide very sensitive analysis of chemical composition and biomolecular interactions. Secondly the wavelength conversion products can be used to generate mid-IR light for remote chemical detection.




SpectroSens - Biochemical Sensing

skematic of antibody bindingSpectroSens chips detect biological or chemical substances and monitor biomolecular interactions by measuring the change on the surface of the sensor. As a surface sensor, SpectroSens chips can be applied to any application that provides detection by interaction with a surface coating or surface preparation, such as an immunoassay. When a pre-applied surface coating is modified by its interaction with the target material the change in its surface properties can be accurately detected. This detection is conducted in a tagless configuration. Binding or other interaction with the surface is detected without having to provide a fluorescent, magnetic or other tag on the target molecule. Unlike other technologies, the depth of surface that is probed can also be tuned to suit different applications or provide additional information to reduce false positives. All of this functionality is provided with a standard glass interface to the sample, making SpectroSens solutions compatible with a wide range of samples and surface preparation techniques.

SpectroSens is unlike competitive technologies such as Surface Plasmon Reasonance (SPR) because it is monolithic and so is very robust, it is also self-referenced on chip to remove temperature effects. A further advantage is that SpectroSens works at multiple wavelengths simultaneously thus providing additional spectral information.

There are many applications of SpectroSens including:

Process Control

Refractive index measurement is often used in industrial process control to monitor changes in liquids. SpectroSens offers a solution to monitor refractive index extremely precisely using small chips which can either be integrated into the processing system or use a small sample tube to draw a very small sample around the detector. The SpectroSens device can monitor refractive index at multiple wavelengths and so give more information on the chemical mixture . The SpectroSens chips are all optical and can be networked with optical fibre making them ideal for instrumentation of processes where flammable liquids are present.

Remote chemical detection using mid-infrared lasers

Mid-infrared lasers can be used for chemical spectroscopy and detection. In the 1.5-5µm region of the spectrum many chemicals have a characteristic absorption spectra and there are also several atmospheric transmission windows in this region of the spectrum which enables remote detection. Mid infra-red lasers sources required for remote sensing have been available for some time in laboratories but are frequently bulky and require power hungry cooling systems. Stratophase is able to offer bespoke compact mid infra-red sources using its periodically poled lithium niobate technology to convert the output of common laser source to the mid-IR region of the spectrum. This technology enables the development of robust, portable, mid IR sources.

Stratophase Ltd | Tel. +44 (0)1794 511226 | Fax. +44 (0)8704 580754 | email: enquiries@stratophase.com